搜索历史清除全部记录
最多显示8条历史搜索记录噢~
All
  • All
  • Product Management
  • News
scroll down

How to measure the axial clearance of the gear pump?

Release time:

2019-05-15

1. Select the appropriate size of the plum wrench (preferably) or open-end wrench; use an outer diameter micrometer of 0 ~ 25mm;
 
2, choose the appropriate soft lead wire diameter (0.5
 
3, pressure wire operation
 
(1) Assembling the main and driven gears;
 
(2) Pasting the three sections of soft lead wire with the grease on the pitch circle of the main and driven gears;
 
(3) Install the pump cover (including the gasket and the bushing), and tighten the nut symmetrically and evenly in 2~3 times;
 
(4) Unscrew the pump cover nut evenly and symmetrically, remove the pump cover, remove the soft lead wire and clean it;
 
(5) Select 4 measuring points on each lead wire piece, measure the thickness of the soft lead wire piece with an outer diameter micrometer and make a measurement record;
 
4, measurement data analysis
 
(1) Calculate the average value of the eight measured values, that is, the axial gap;
 
(2) According to the measured axial gap value and the normal value range (generally 0.06 ~ 0.10mm, low pressure gear pump allowed to 0.10 ~ 0.25mm), make the conclusion that it can continue to use or need to be repaired.